Boiler Pressure Keeps Dropping? What It Means and What to Do in Woking Homes

If your boiler pressure gauge keeps slipping below 1 bar, the boiler will eventually lock out and leave you with no heating or hot water. It is one of the most common callouts for HP Heating across Woking — and most causes are simple to explain.

Why pressure drops

A small leak somewhere on the system. Check radiator valves, bleed valves and visible pipework for damp patches or green/white crusty residue. Even a slow weep drops pressure over days.

A faulty pressure relief valve. If the copper discharge pipe outside drips constantly, the valve may be passing and need replacing.

A failing expansion vessel. If pressure spikes high when the heating is on, then crashes when it cools, the vessel has usually lost its air charge.

Recently bled radiators. Bleeding lets air out — and pressure out with it. Topping back up to 1–1.5 bar afterwards is normal.

What you can safely do yourself

Use the filling loop to top the system back up to between 1 and 1.5 bar when cold, then keep an eye on it. If it holds, you are fine. If it keeps falling within days, do not keep topping up forever — the fresh water you add brings oxygen that corrodes radiators from the inside.

When to call a professional

If pressure drops repeatedly, the relief valve drips, or the gauge swings wildly, get the system checked. A proper boiler repair in Woking finds the real cause instead of masking it. An annual boiler service in Woking catches most of these faults early — and if the boiler dies completely on a cold night, an emergency plumber in Guildford is one call away.